Cell Type | Monocrystalline |
Rated Power (Pm) | 110W |
Maximum Power (Vmp) | 17.6V |
Maximum Power Current (Imp) | 6.31A |
Open Circuit Voltage (Voc) | 22.08V |
Short Circuit Current (Isc) | 6.60A |
Maximum System Voltage | 600VDC |
Weight | 2.9 lb (1.35 kg) |
Dimensions | 44.6 x 21.4 x 0.1 in (1134 x 544 x 3 mm) |
SPECIFICATIONS |
|
No-Load Loss |
<10mA |
Grounding |
Negative |
Operating Temperature |
-40 to 50°C |
Storage Temperature |
-60 to 85°C |
Humidity |
95% N.C. |
Water Ingress Protection |
IP68 |
Altitude |
< 3000m |
Standards Compliance |
UL 1741,FCC Part 15 Class B, CE, RoHS |
Protection |
Solar/Bat1/Bat2 Reverse Polarity Solar/Bat1/Bat2 Over Voltage Solar Short Circuit Over Temperature |
Dimensions |
14.4 x 7.6 x 4.13in (366 x 194 x 105mm) |
SOLAR INPUT |
|
Max Input Current |
30A |
MPPT Tracking Efficiency |
>99% |
Max Input Voltage |
150Voc |
Max Input Power |
600W (12V) / 1200W (24V) |
Wire Gauge |
8 AWG |
Connectors |
MC4 |
Conversion Efficiency |
≤98% |
BUCK-BOOST CONVERTER |
|
Conversion Efficiency |
12V/24V |
Input Voltage Range |
8V – 32V |
Max Input Power |
-3mv/°C/2V, none for Lithium batteries |
Max Charge Current |
30A |
Wire Gauge |
8 AWG |
External Input Connector |
2-way Aptiv Metri-Pack 630 Male Connector |
BATTERY OUTPUTS |
|
System Voltage |
12V/24V |
Voltage Range |
8V – 32V |
Temperature Compensation |
-3mv/°C/2V, none for Lithium batteries |
Max Output Current |
30A |
Supported Battery Types |
Lead Acid (AGM, Gel, Flooded), LiFePO4 |
Wire Gauge |
8 AWG |
Connectors |
2-way Aptiv Metri-Pack 630 Male Connector |
CHARGING PROFILE |
SEALED/GEL |
AGM |
FLOODED |
LIFEPO4 |
CUSTOM |
High Voltage Disconnect |
16.0 / 32.0 V |
16.0 / 32.0 V |
16.0 / 32.0 V |
14.6 / 29.2V |
8 – 32 V |
Equalize Voltage |
– |
– |
14.9 / 29.8V |
– |
8 – 32 V |
Bulk-Absorption Voltage |
14.1 / 28.2 V |
14.4 / 28.8 V |
14.4 / 28.8 V |
14.2 / 28.4 V |
8 – 32 V |
Float Voltage |
13.7 / 27.4 V |
13.7 / 27.4 V |
13.7 / 27.4 V |
14.0 / 28.0 V |
8 – 32 V |
Recharge Voltage |
13.2 / 26.4 V |
8 – 32 V |
|||
Over-Discharge Return Voltage |
12.8 / 25.2 V |
12.8 / 25.2 V |
12.8 / 25.2 V |
12.2 / 24.4 V |
8 – 32 V |
Under-Voltage Warning Level |
12.0 / 24.0 V |
8 – 32 V |
|||
Discharge Limit Voltage |
10.5 / 21.0 V |
8 – 32 V |
|||
Over-Discharge Time Delay |
10 seconds |
0 – 120 seconds |
|||
Equalize Duration |
– |
– |
120 minutes |
– |
0 – 600 minutes |
Absorption Duration |
120 minutes |
10 – 600 minutes |
|||
Equalize Interval |
– |
– |
30 days |
– |
0 – 250 days |
Temperature Compensation Factor |
-24 mV/°C |
– |
0 – 30 mV/°C |